SuperServer 1028U-TNRTP+
- Nhà sản xuất: SUPERMICRO
- Mã sản phẩm: SuperServer 1028U-TNRTP+
- Tình trạng: Còn hàng
- 0 VNĐ
- Giá chưa VAT: 0 VNĐ
Số lượng
Thông tin sản phẩm SuperServer 1028U-TNRTP+
Key Features
1. Dual socket R3 (LGA 2011) supports Intel® Xeon® processor E5-2600 v3 family;
QPI up to 9.6GT/s
2. Up to 1.5TB ECC, up to DDR4 2133MHz; 24x DIMM slots
3. 2x PCI-E 3.0 x16 slots (FH, 10.5" L), 2x PCI-E 3.0 x8 slots (LP, 1 internal)
4. 2x 10G SFP+ ports
5. 10x Hot-swap 2.5" Drive Bays:
Default 8x SATA3 ports and 2x NVMe/SATA3 hybrid ports;
Optional 8x SAS3 ports via AOC
6. 5x heavy duty fans w/ optimal an speed control
7. 750W Redundant Power Supplies Platinum Level (94%+)
Specifications
Product SKUs |
|
SYS-1028U-TNRTP+ | SuperServer 1028U-TNRTP+ (Black) |
Motherboard |
|
Super X10DRU-i+ | |
Processor/Cache |
|
CPU | Intel® Xeon®
processor E5-2600 v3 family (up to 160W TDP) * Dual Socket R3 (LGA 2011) |
Cores / Cache | Up to 18 Cores / Up to 45MB Cache |
System Bus | QPI up to 9.6 GT/s |
Note | * Please contact Supermicro Technical Support for additional information about frequency optimized CPUs and specialized system optimization. |
System Memory |
|
Memory Capacity | 24x 288-pin DDR4
DIMM slots Up to 1.5TB ECC LRDIMM, RDIMM |
Memory Type | 2133/1866/1600MHz ECC DDR4 SDRAM 72-bit |
DIMM Sizes | 64GB, 32GB, 16GB, 8GB, 4GB |
Memory Voltage | 1.2 V |
Error Detection | Corrects single-bit errors |
On-Board Devices |
|
Chipset | Intel® C612 chipset |
SATA | SATA3 (6Gbps) with RAID 0, 1, 5, 10 |
IPMI | Support for
Intelligent Platform Management Interface v.2.0 IPMI 2.0 with virtual media over LAN and KVM-over-LAN support ASPEED AST2400 BMC |
Network Connectivity | 2x 10G SFP+ ports via AOC-URN2-I2XS |
Graphics | ASPEED AST2400 BMC |
Input / Output |
|
SATA | 10x SATA3 (6Gbps) ports |
SAS | 8x SAS3 ports support via optional Add-on Card |
NVMe | 2x NVMe ports |
LAN | 2x 10G SFP+ ports 1x RJ45 Dedicated IPMI LAN port |
USB | 5x USB 3.0 ports (2 rear, 2 front, 1 Type A) |
Video | 1x VGA Connector |
Serial Port | 1x Serial header |
System BIOS |
|
BIOS Type | 128Mb SPI Flash EEPROM with AMI BIOS |
BIOS Features | Plug and Play
(PnP) APM 1.2 PCI 2.3 ACPI 1.0 / 2.0 / 3.0 / 4.0 USB Keyboard support SMBIOS 2.7.1 UEFI 2.3.1 |
Management |
|
Software | SuperDoctor®
5 Intel® Node Manager 3.0 Watch Dog NMI SMCBU and SMM Optional IPMI 1.5 / 2.0 |
Power Configurations | ACPI
Power Management Power-on mode for AC power recovery |
Chassis |
|
Form Factor | 1U Rackmount |
Model | CSE-119UAC2-R750 |
Dimensions and Weight |
|
Height | 1.7" (43mm) |
Width | 17.2" (437mm) |
Depth | 27.82" (707mm) |
Weight | Net Weight: 26 lbs
(11.8 kg) Gross Weight: 41 lbs (18.6 kg) |
Available Color | Black |
Front Panel |
|
Buttons | Power On/Off
button System UID button |
LEDs | Power LED Hard drive activity LED 2x Network activity LEDs System Overheat LED / Fan fail LED / UID LED |
Expansion Slots |
|
PCI-Express | 2x PCI-E 3.0 x16
slots (Full-height, 10.5" L) 2x PCI-E 3.0 x8 slots (Low-profile, 1 internal) (Both CPUs need to be installed for full access to PCI-E slots and onboard controllers. See manual block diagram and AOC Support for details.) |
Drive Bays |
|
Hot-swap | 10x 2.5" Hot-swap
drive bays Default 8x SATA3 ports and 2x NVMe/SATA3 hybrid ports Optional 8x SAS3 ports via AOC |
System Cooling |
|
Fans | 5x heavy duty fans
with optimal fan speed control 3x additional fans optional |
Air Shroud | 1x Air Shroud |
Power Supply |
|
750W Redundant AC-DC Power Supplies, +12V/+12Vsb output | |
AC Input | 100-127Vac,
50-60Hz 200-240Vac, 50-60Hz |
+12V | Max: 62.5A & Min:
0A (100Vac-127Vac) Max: 62.5A & Min: 0A (200Vac-240Vac) |
12V SB | Max: 2.1A Min: 0A |
Certification | Platinum Level |
PC Health Monitoring |
|
Voltage | Monitors for CPU
Cores, +1.8V, +3.3V, +5V, +12V, +3.3V Standby, +5V Standby, VBAT, Memory
Voltages. 5+1 Phase-switching voltage regulator |
FAN | 8x 4-pin fan
headers Status monitor for speed control Pulse Width Modulated (PWM) fan connectors |
Temperature | Support to monitor
Supermicro AOC temperatures from IPMI or SD 5 Monitoring for CPU and chassis environment CPU thermal trip support Thermal Control for 8x Fan Connectors Thermal Monitor 2 (TM2) support PECI |
LED | Memory DIMM ECC
error LEDs CPU / System Overheat LED Suspend static indicator LED UID/Remote UID |
4x 8-pin GPU power
connectors Chassis intrusion detection Chassis intrusion header SDDC Support RoHS |
|
Other Features | |
Operating Environment / Compliance |
|
RoHS | RoHS Compliant |
Environmental Spec. | Operating
Temperature: 10°C to 35°C (50°F to 95°F) Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) |
Standard Parts List |
|||
Part Number | Qty | Description | |
Motherboard / Chassis | MBD-X10DRU-i+ | 1 | Super X10DRU-i+ Motherboard |
CSE-119UAC2-R750 | 1 | CSE-119UAC2-R750 Chassis | |
Air Shroud | MCP-310-81903-0B | 1 | Mylar air shroud set for SC819U,119U (X10DRU+),HF |
Add-on Card / Module | AOC-URN2-I2XS | 1 | 1U Ultra Riser based on Intel 82599ES controller with 2 10Gb SFP+ ports, 2 NVMe ports, and 1 internal PCI-E x8 3.0 slot |
Backplane | BPN-SAS3-116A-N2 | 1 | 10-Port 1U Backplane for 8x2.5\" SAS3/SATA3 HDD/SSD and 2xSAS2/SATA3 HDD/SSD or NVMe SSD |
Cable 1 | CBL-SAST-0658 | 2 | Internal Mini-SAS HD cable for PCIe SSD NVMe, 12Gb/s, 60cm,30AWG,RoHS/REACH |
Cable 2 | CBL-0484L | 2 | 55cm 30AWG SATA S-S cable |
Cable 3 | CBL-PWEX-0653 | 1 | 8 pin female to 4 pin female power, 37cm, 18AWG,RoHS/REACH |
Cable 4 | CBL-CDAT-0662 | 1 | 8 pin to 8 pin round SGPIO cable, 61.5cm, 28AWG, pinout 1-1,RoHS/REACH |
Cable 5 | CBL-PWEX-0650 | 1 | 8 pin female to 2x RA(Right Angle) big 4 pin female power, 47/62CM, 18AWG,RoHS/REACH |
Cable 6 | CBL-SAST-0655 | 1 | Internal RA side exit (right) miniSAS to miniSAS HD 47cm w/ SB, 30AWG,RoHS/REACH |
Cable 7 | CBL-SAST-0656 | 1 | Internal RA side exit (right) miniSAS to miniSAS HD 39cm w/ SB, 30AWG,RoHS/REACH |
Drive Tray(s) | MCP-220-00127-0B | 2 | Black gen-3 2.5 NVMe drive tray, Orange tab with lock (for hotswap NVMe drive),HF,RoHS/REACH |
Label | LBL-0108 | 1 | CAUTION LABEL FOR REDUNDANT PWR SYSTEMS |
Manual | MNL-1678-QRG | 1 | SYS-1028U-TR(4/4T/T/TP)+, QRG,HF,RoHS/REACH |
Riser Card | RSC-R1UW-2E16 | 1 | RSC-R1UW-2E16-O-P |
Riser Card | RSC-R1UW-E8R | 1 | RSC-R1UW-E8R-O-P |
Rear Window | MCP-240-81910-0N | 1 | MCP-240-81910-0N Ultra I/O rear window for SC819U, 119U-T (i2XS) |
Heatsink / Retention | SNK-P0047PS | 2 | 1U Passive CPU Heat Sink for X9, X10 Systems Equipped w/ a Narrow ILM MB |
Fan | FAN-0101L4 | 1 | 40x56,4 Pin PWM,Primary for SC809,111, Sec.for SC816,819,808 |
Power Supply | PWS-751P-1R | 2 | 1U 750W Redundant Platinum Single Output Power Supply w/Pmbus W73.5xH40xL203mm,RoHS/REACH |
Mounting Rails | MCP-290-00102-0N | 1 | Outer rail, quick-release type, 25.6" to 33.05" |
MCP-290-00120-0N | 1 | Inner rail, front, quick-release type (thumb screw applied) | |
MCP-290-00112-0N | 1 | Inner rail, extension, long (quick) for 1U 17.2"W chassis |
Optional Parts List |
|||
Part Number | Qty | Description | |
Mounting Rails | MCP-290-00062-0N | - | Inner/outer rail set, quick-release type, 25.6" to 33.05" |
MCP-290-00064-0N | - | Thumb screw adapter of inner rail for 1U 17.2" | |
MCP-290-00052-0N-BULK | - | Bulk outer rail, quick-release type, 25.6" to 33.05" (10 sets/pack) | |
10GbE SFP+ Direct Attach Cable (DAC,
copper wire)
|
CBL-0347L | - | 1M 10G SFP+ to SFP+ Passive Copper M-M Pull type 30AWG |
CBL-0348L | - | 3M 10G SFP+ to SFP+ Passive Copper M-M Pull type 24AWG | |
CBL-0349L | - | 5M 10G SFP+ to SFP+ Passive Copper M-M Pull type 24AWG | |
CBL-NTWK-0347 | - | 1M 10G SFP+ to SFP+ Passive Copper M-M Push type 30AWG | |
CBL-NTWK-0456 | - | 2M 10G SFP+ to SFP+ Passive Copper M-M Push type 30AWG | |
Storage Control Card and Cable(s) |
AOC-S3008L-L8e & 2x CBL-SAST-0593 |
- | Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s |
AOC-S3008L-L8i & 2x CBL-SAST-0593 |
- | Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s | |
AOC-S3108L-H8iR & 2x CBL-SAST-0593 |
- | Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60; Internal Mini-SAS HD to Mini-SAS HD 60cm,30AWG,12Gb/s | |
Network Card(s) | AOC-S40G-i2Q | - | Standard LP 2-port 40GbE controller, based on Intel Fortville XL710 |
AOC-SGP-i2 | - | Standard LP, 2x GbE RJ45, PCI-E x4, Intel i350AM2 | |
AOC-SGP-i4 | - | Standard LP, 4x GbE RJ45, PCI-E x4, Intel i350 | |
AOC-STG-b4S | - | Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S | |
AOC-STGN-i2S | - | Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel 82599ES | |
AOC-STGN-i1S | - | Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel 82599EN | |
AOC-STG-i2T | - | Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540 | |
AOC-STG-i2 | - | Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB | |
CachVault(s) | BTR-CV3108-1U1 | - | CacheVault for LSI 3108 with Supercap mounting in 1U 40x56 fan tray |
BTR-TFM8G-LSICVM02 & BKT-BBU-BRACKET-05 | - | CacheVault for LSI 3108; Supercap mounting bracket for PCI-E location | |
BTR-TFM8G-LSICVM02 & MCP-240-00127-0N | - | CacheVault for LSI 3108; Supercap mounting bracket for 2.5" HDD location | |
Fan | FAN-0101L4 | Up to 3 | 40x40x56 mm, 14.4K-10.7K RPM Counter-rotating Cooling Fan |